The HBM HLCB1C3 Shear Beam Load Cell is a shear beam or bending beam load cell. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as HBM and the model / part number as 1-HLCB1C3.
Shear and bending beam cells are common choices for floor scales, livestock platforms, tanks, hoppers, and low-to-mid capacity industrial scales.
A practical load-cell family for fabricated platforms and summing-box systems.
Works well when mounts control side load and vessel movement.
Often used in platform and chute builds when capacity and environmental rating fit.
Confirm the rated capacity against dead load, live load, impact, and load distribution.
Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.
Catalog protection is IP68. Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.
Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.
The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.
| Material | Stainless steel (Viton seal) |
| Protection | IP68 |
| Signal | Analog |
| Manufacturer | HBM |
| Approval | OIML R60 C3 · NTEP Class IIIM |
| Rated output | 1.94 mV/V (2.00 mV/V at 10 t) |
| Recommended excitation | 5 V (range 0.5–15 V) |
| Maximum excitation | 15 V |
| Input impedance | 350–480 Ω |
| Output impedance | 350 ± 2 Ω |
| Insulation resistance | > 5 GΩ |
| Creep error | ≤ ±0.0166 %Cn / 30 min (C3) |
| Safe overload | 150 %Emax |
| Operating temperature | −30 to +70 °C |
| Output sensitivity | 1.94 mV/V (2.00 mV/V at 10 t) |
| Non-linearity | ≤ ±0.0170 %Cn (C3) |
| Compensated temperature | −10 to +40 °C |
| Storage temperature | −50 to +85 °C |
| Safe side load | 100 %Emax |
| Product | Order code |
|---|---|
| HBM HLCB1C3 Shear Beam Load Cell | 1-HLCB1C3 |
No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.
Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.
Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 1-HLCB1C3 is the right fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305| Signal | Analog |
|---|---|
| Protection class | IP68 |
| Material | Stainless Steel |
| Compensated temp range | −10 to +40 °C |
| Creep error 20mins | ≤ ±0.0166 %Cn / 30 min (C3) |
| Input impedance | 350–480 Ω |
| Insulation resistance | > 5 GΩ |
| Internal Battery | -- |
| Maximum excitation | 15 V |
| Maximum safe overload | 150 %Emax |
| Operating temp range | −30 to +70 °C |
| Output impedance | 350 ± 2 Ω |
| Rated output | 1.94 mV/V (2.00 mV/V at 10 t) |
| Recommended excitation | 5 V (range 0.5–15 V) |
| Safe sideload | 100 %Emax |
| Storage temp range | −50 to +85 °C |
| Manufacturer | HBM |
| Approval | OIML R60 C3 |