The Zemic L6E-200kg L6E-C3 Single Point Load Cell is a single point load cell rated 200kg. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Zemic and the model / part number as 21155.
Single point cells are selected around platform size, off-center loading behavior, capacity, material, and approval requirements.
Best fit for compact scales where one cell supports the full platform.
A common choice for small weighing stations that need repeatability under off-center loading.
Confirm maximum platform size and mounting pattern before replacing another brand.
Confirm 200kg against dead load, live load, impact, and load distribution.
Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.
Catalog protection is IP65 (EN 60529). Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.
Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.
The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.

| Material | Aluminium |
| Protection | IP65 (EN 60529) |
| Signal | Analog |
| Capacity weight | 200 kg |
| Approval | OIML R60 C3 (TC7838) |
| Max platform size | 400 × 400 mm |
| Recommended excitation | 5 ~ 12 VDC |
| Maximum excitation | 18 VDC |
| Input impedance | 406 ± 6 Ω |
| Output impedance | 350 ± 3 Ω |
| Insulation resistance | ≥ 5000 MΩ @ 50 VDC |
| Combined error | ≤ ±0.023 %FS (C3) |
| Creep error | ≤ ±0.0167 %FS / 30 min (C3) |
| Safe overload | 150 %FS |
| Ultimate overload | 200 %FS |
| Operating temperature | −35 to +65 °C |
| Number of wires | 4 |
| Zero balance | ≤ ±2.0 %FS |
| Compensated temperature | −10 to +40 °C |
| Storage temperature | −40 to +70 °C |
| Product | Order code |
|---|---|
| Zemic L6E-200kg L6E-C3 Single Point Load Cell | 21155 |
No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.
Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.
Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 21155 is the right fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305| Signal | Analog |
|---|---|
| Protection class | IP65 |
| Material | Aluminum |
| Combined error | ≤ ±0.023 %FS (C3) |
| Compensated temp range | −10 to +40 °C |
| Creep error 20mins | ≤ ±0.0167 %FS / 30 min (C3) |
| Input impedance | 406 ± 6 Ω |
| Insulation resistance | ≥ 5000 MΩ @ 50 VDC |
| Internal Battery | -- |
| Maximum excitation | 18 VDC |
| Maximum safe overload | 150 %FS |
| Max platform size | 400 × 400 mm |
| Operating temp range | −35 to +65 °C |
| Output impedance | 350 ± 3 Ω |
| Recommended excitation | 5 ~ 12 VDC |
| Storage temp range | −40 to +70 °C |
| Ultimate central overload | 200 %FS |
| Zero balance | ≤ ±2.0 %FS |
| Number of Wires | 4 wires |
| Approval | OIML R60 C3 |