L6G Single Point Load Cell · 100 kg · L6G-C3-100kg-3G6Zemic L6G-100kg L6G-C3-100KG-3G6 Single Point Load Cell
- Description
- Additional Information
- 01 / 07Single point load cells
Single point load cells for confirmed-fit replacement and scale builds.
The Zemic L6G-100kg L6G-C3-100KG-3G6 Single Point Load Cell is a single point load cell rated 100kg. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Zemic and the model / part number as L6G-C3-100kg-3G6.
100kgRated capacityAluminiumMaterialIP65ProtectionAnalogSignal02 / 07Application fitWhere this load cell belongs.
Single point cells are selected around platform size, off-center loading behavior, capacity, material, and approval requirements.
01Bench and retail platforms
Best fit for compact scales where one cell supports the full platform.
platform02Counting and pricing scales
A common choice for small weighing stations that need repeatability under off-center loading.
bench scale03Replacement work
Confirm maximum platform size and mounting pattern before replacing another brand.
retrofit03 / 07Mechanical and electrical fitConfirm the details before replacement.
CAPACITYCapacity and load path
Confirm 100kg against dead load, live load, impact, and load distribution.
MECHANICALMechanical fit
Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.
ENVIRONMENTEnvironment
Catalog protection is IP65. Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.
ELECTRICALElectrical match
Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.
04 / 07Installation notesA load cell is only correct when the assembly around it is correct.
The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.
- Match mounting holes, load point, thread, and installed height
- Confirm cell count and junction-box wiring
- Confirm material and protection rating for the environment
- Confirm rated output, excitation, and input/output impedance
- Keep datasheets, photos, and old part numbers with the service record
05 / 07Dimensions and connectionsUse the available images to confirm the mechanical envelope and cable connection.

Dimension reference 06 / 07Technical dataCatalog attributes for this load cell.
Material Aluminium Protection IP65 Signal Analog Manufacturer Zemic Manufacturer part number L6G-C3-100kg-3G6 Capacity weight 100 kg Accuracy C3 Max platform size 600 × 600 mm Rated output 2.0 ± 0.2 mV/V Recommended excitation 5 ~ 12 VDC Maximum excitation 18 VDC Input impedance 406 ± 6 Ω Output impedance 350 ± 3 Ω Insulation resistance ≥ 5000 MΩ @ 50 VDC Combined error ≤ ±0.020 %FS Creep error ≤ ±0.0167 %FS / 30 min Safe overload 120 %FS Ultimate overload 150 %FS Operating temperature −35 to +65 °C Number of wires 6 Zero balance ≤ ±2.0 %FS Compensated temperature −10 to +40 °C 07 / 07Part number referenceOrder code and fit FAQ.
Product Order code Zemic L6G-100kg L6G-C3-100KG-3G6 Single Point Load Cell 11698 Is the SKU enough to confirm replacement?
No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.
What if some catalog attributes are blank?
Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.
Can WeightechUSA help identify a match?
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.
Talk to a WeightechUSA load-cell specialist.
Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 11698 is the right fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305DIMENSIONSOutline dimensions.

Source: Zemic L6G datasheet Signal Analog Protection class IP65 Material Aluminum Combined error ≤ ±0.020 %FS Compensated temp range −10 to +40 °C Creep error 20mins ≤ ±0.0167 %FS / 30 min Eccentric loading error ≤ 0.002 %LD/cm Input impedance 406 ± 6 Ω Insulation resistance ≥ 5000 MΩ @ 50 VDC Internal Battery No Maximum excitation 18 VDC Maximum number of intervals 3000 nLC Maximum safe overload 120 %FS Max platform size 600 × 600 mm NTEP/OIML OIML R60 C3 · R60/2000-CN1-00.03 Revision 1 · NTEP 23-031 Operating temp range −35 to +65 °C Output impedance 350 ± 3 Ω Rated capacity 100 kg Rated output 2.0 ± 0.2 mV/V Recommended excitation 5 ~ 12 VDC Recommended torque M8: 25 Nm Ultimate central overload 150 %FS Zero balance ≤ ±2.0 %FS Manufacturer Zemic Accuracy C3 Interchangeable Celtron LOC, Revere 672, Tedea 1263 Number of Wires 6 wires Manufacturer's Part Number L6G-C3-100kg-3G6 Approval NTEP, OIML R60 C3 Short name L6G Single Point Load Cell · 100 kg · L6G-C3-100kg-3G6 Hero chips IP65; Aluminum; Analog signal; OIML R60 C3; NTEP; 6 wires