
The Laumas AZLI500-500kg Single Point Load Cell is a single point load cell rated 500 kg. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Laumas and the model / part number as AZLI500.
Single point cells are selected around platform size, off-center loading behavior, capacity, material, and approval requirements.
Best fit for compact scales where one cell supports the full platform.
A common choice for small weighing stations that need repeatability under off-center loading.
Confirm maximum platform size and mounting pattern before replacing another brand.
Confirm 500 kg against dead load, live load, impact, and load distribution.
Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.
Catalog protection is IP68. Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.
Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.
The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.
| Material | 17-4 PH Stainless Steel |
| Protection | IP68 |
| Signal | Analog |
| Cable length | 3 m |
| Cable type | 4/6 x 0.20 mm² shielded |
| Manufacturer | Laumas |
| Manufacturer part number | AZLI500 |
| Rated capacity | 500 kg |
| Capacity | 500 kg |
| Capacity weight | 500 kg |
| Sealing | Hermetically Sealed |
| Approval | OIML R60 C3 |
| Max platform size | 800 x 800 mm |
| Thread | Metric Thread |
| Rated output | 2 mV/V |
| Rated output tolerance | ±10% |
| Input impedance | 350 Ω ±3.5 |
| Output impedance | 350 Ω ±3.5 |
| Insulation resistance | ≥5000 MΩ |
| Combined error | ≤ ±0.02% |
| Safe overload | 150% of full scale |
| Ultimate overload | 300% of full scale |
| Operating temperature | -35 °C / +65 °C |
| Product | Order code |
|---|---|
| Laumas AZLI500-500kg Single Point Load Cell | 23278 |
No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.
Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.

Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 23278 is the right fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305| Signal | Analog |
|---|---|
| Protection class | IP68 |
| Material | 17-4 PH Stainless Steel |
| Combined error | ≤ ±0.02% |
| Compensated temp range | -10 °C / +40 °C |
| Creep error 30 mins | 0.02% |
| Deflection at E max | 0.5 mm |
| Input impedance | 350 Ω ±3.5 |
| Insulation resistance | ≥5000 MΩ |
| Internal Battery | -- |
| Maximum number of intervals | 3000 (C3) |
| Maximum safe overload | 150% of full scale |
| Max platform size | 800 x 800 mm |
| Minimum load cell verification interval | E max / 10000 (C3) |
| Nominal rated load | 500 kg |
| NTEP/OIML | OIML R60 C3, NTEP (legal for trade), UKCA and EAC |
| Operating temp range | -35 °C / +65 °C |
| Output impedance | 350 Ω ±3.5 |
| Rated capacity | 500 kg |
| Rated output | 2 mV/V |
| Rated output tolerance | ±10% |
| Recommended torque | M8: 19 Nm (class 6.8) / 25 Nm (class 8.8) |
| Temp effect on output | 0.0014 %/°C |
| Temp effect on zero | 0.0017 %/°C |
| Ultimate central overload | 300% of full scale |
| Zero balance | ±2% |
| Manufacturer | Laumas |
| Capacity | 500 kg |
| Cable type | 4/6 x 0.20 mm² shielded |
| Cable length | 3 m |
| Thread - Clevis | Metric Thread |
| Sealing | Hermetically Sealed |
| Manufacturer's Part Number | AZLI500 |
| Approval | OIML R60 C3 |
| Short name | AZLI500-500kg Single Point |
| Hero chips | 500 kg; IP68; 17-4 PH Stainless Steel; Analog signal; OIML R60 C3 |