AZLI500-500kg Single PointLaumas AZLI500-500kg Single Point Load Cell
- Description
- Additional Information
- 01 / 06Single point load cells
Single point load cells for confirmed-fit replacement and scale builds.
The Laumas AZLI500-500kg Single Point Load Cell is a single point load cell rated 500 kg. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Laumas and the model / part number as AZLI500.
500 kgRated capacity17-4 PH Stainless SteelMaterialIP68ProtectionAnalogSignal02 / 06Application fitWhere this load cell belongs.
Single point cells are selected around platform size, off-center loading behavior, capacity, material, and approval requirements.
01Bench and retail platforms
Best fit for compact scales where one cell supports the full platform.
platform02Counting and pricing scales
A common choice for small weighing stations that need repeatability under off-center loading.
bench scale03Replacement work
Confirm maximum platform size and mounting pattern before replacing another brand.
retrofit03 / 06Mechanical and electrical fitConfirm the details before replacement.
CAPACITYCapacity and load path
Confirm 500 kg against dead load, live load, impact, and load distribution.
MECHANICALMechanical fit
Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.
ENVIRONMENTEnvironment
Catalog protection is IP68. Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.
ELECTRICALElectrical match
Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.
04 / 06Installation notesA load cell is only correct when the assembly around it is correct.
The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.
- Match mounting holes, load point, thread, and installed height
- Confirm cell count and junction-box wiring
- Confirm material and protection rating for the environment
- Confirm rated output, excitation, and input/output impedance
- Keep datasheets, photos, and old part numbers with the service record
05 / 06Technical dataCatalog attributes for this load cell.
Material 17-4 PH Stainless Steel Protection IP68 Signal Analog Cable length 3 m Cable type 4/6 x 0.20 mm² shielded Manufacturer Laumas Manufacturer part number AZLI500 Rated capacity 500 kg Capacity 500 kg Capacity weight 500 kg Sealing Hermetically Sealed Approval OIML R60 C3 Max platform size 800 x 800 mm Thread Metric Thread Rated output 2 mV/V Rated output tolerance ±10% Input impedance 350 Ω ±3.5 Output impedance 350 Ω ±3.5 Insulation resistance ≥5000 MΩ Combined error ≤ ±0.02% Safe overload 150% of full scale Ultimate overload 300% of full scale Operating temperature -35 °C / +65 °C 06 / 06Part number referenceOrder code and fit FAQ.
Product Order code Laumas AZLI500-500kg Single Point Load Cell 23278 Is the SKU enough to confirm replacement?
No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.
What if some catalog attributes are blank?
Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.
Can WeightechUSA help identify a match?
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.
DIMENSIONSOutline dimensions.

Source: manufacturer datasheet Talk to a WeightechUSA load-cell specialist.
Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 23278 is the right fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305 Signal Analog Protection class IP68 Material 17-4 PH Stainless Steel Combined error ≤ ±0.02% Compensated temp range -10 °C / +40 °C Creep error 30 mins 0.02% Deflection at E max 0.5 mm Input impedance 350 Ω ±3.5 Insulation resistance ≥5000 MΩ Internal Battery -- Maximum number of intervals 3000 (C3) Maximum safe overload 150% of full scale Max platform size 800 x 800 mm Minimum load cell verification interval E max / 10000 (C3) Nominal rated load 500 kg NTEP/OIML OIML R60 C3, NTEP (legal for trade), UKCA and EAC Operating temp range -35 °C / +65 °C Output impedance 350 Ω ±3.5 Rated capacity 500 kg Rated output 2 mV/V Rated output tolerance ±10% Recommended torque M8: 19 Nm (class 6.8) / 25 Nm (class 8.8) Temp effect on output 0.0014 %/°C Temp effect on zero 0.0017 %/°C Ultimate central overload 300% of full scale Zero balance ±2% Manufacturer Laumas Capacity 500 kg Cable type 4/6 x 0.20 mm² shielded Cable length 3 m Thread - Clevis Metric Thread Sealing Hermetically Sealed Manufacturer's Part Number AZLI500 Approval OIML R60 C3 Short name AZLI500-500kg Single Point Hero chips 500 kg; IP68; 17-4 PH Stainless Steel; Analog signal; OIML R60 C3