The Laumas TLBPOWERLINK is the PowerLink output/fieldbus option of the Laumas TLB digital weight transmitter family.
| Manufacturer | Laumas |
| Manufacturer part number | TLBPOWERLINK |
| Output/Fieldbus | PowerLink |
| Channels | 1 load-cell input |
| Power supply | 12-24 VDC +/-10%, 5 W |
| Load cells | Up to 8 x 350 ohm, 4/6-wire, 5 VDC/120 mA excitation |
| A/D converter | 24-bit (16,000,000 points), 4.8 kHz |
| Measurement range | +/-39 mV |
| Usable load cell sensitivity | +/-7 mV/V |
| Display | 6-digit semi-alphanumeric red LED, 8 mm height, +/-999999 range |
| Relay outputs | 3, max 115 VAC/150 mA |
| Optoisolated digital inputs | 2, 5-24 VDC PNP |
| Enclosure | Back-panel mounting on Omega/DIN rail, 115 x 25 x 120 mm |
| Humidity | 85% (condensate-free) |
| Storage temperature | -30 C to +80 C |
| Working temperature | -20 C to +60 C |
| Legal-for-trade approval | OIML R76:2006 Class III, 3x10,000 divisions, 0.2 uV/V*SI; NTEP nmax 5000 Class III; Measurement Canada nmax 5000 Class III |
| Port | 2x POWERLINK ports (RJ45 10Base-T or 100Base-TX, auto-sensing) |
| Network role | Slave in a Powerlink network |
| Serial port | RS485 (included) |
| Product | Order code |
|---|---|
| Laumas TLBPOWERLINK PowerLink Digital Weight Transmitter | 23090 |
Use the SKU and manufacturer part number above as the order code, then confirm wiring, signal, and environment with WeightechUSA before ordering.
Yes. Send photos of the installed equipment, the label, the model and option you need, and the application.
Send the model, the option you need, and the application. We will confirm the manufacturer part number and fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305| Number of divisions | ±999999 • 0.01 μV/d (with measurement range ±10 mV and sensitivity 2 mV/V) |
|---|---|
| Digital filter | 21 levels • 5÷600 Hz |
| Input power supply | 12÷24 VDC ±10%; 5 W |
| Internal Battery | -- |
| Storage temp range | -30 °C +80 °C |
| Number of load cells | up to 16 (350 Ω) - 4/6 wires • 5 VDC/240 mA |
| Fieldbus | PowerLink |
| Linearity - Analog output linearity (only for TLB4) | <0.01% full scale • <0.01% full scale |
| Thermal Drift | Analog output thermal drift (only for TLB4) <0.0005% full scale/°C • <0.003% full scale/°C |
| A/D Converter | 1 channel - 24 bit (16000000 points) - 4.8 kHz |
| Measurement range | ±39 mV |
| Usable load cells sensitivity | ±7 mV/V |
| Conversions per second | 600/s |
| Display range | ±999999 |
| Decimals | 0÷4 • x1 x2 x5 x10 x20 x50 x100 |
| Relay outputs | 3 - max 115 VAC/150 mA |
| Optoisolated digital inputs | 2 - 5÷24 VDC PNP |
| Serial ports | RS485 |
| Baud rate | 2400, 4800, 9600, 19200, 38400, 115200 (bit/s) |
| Optoisolated analog output (only for TLB4) | 16 bit = 65535 divisions. 0÷20 mA; 4÷20 mA (up to 300 Ω) 0÷10 V; 0÷5 V; ±10 V; ±5 V (min 10 kΩ) |
| Humidity | 85% |
| Working temp range | -20 °C +60 °C |
| Manufacturer's Part Number | TLBPOWERLINK |
| Short name | TLB Weight Transmitter · PowerLink · TLBPOWERLINK |
| Hero chips | PowerLink; RS485; 12÷24 VDC |