The Laumas TLM8 Ethernet/IP is an 8-channel digital weight transmitter for analog load cells, combining digital equalization, automatic diagnostics, local LCD/keypad setup, RS485 communication, and a dedicated Ethernet/IP interface.
Use this model when a multi-load-cell scale, tank, hopper, platform, or process weighing system needs individual channel monitoring and direct PLC or host integration.

Use one transmitter for up to eight analog load-cell channels with digital equalization.
Select this TLM8 version when the control system requires Ethernet/IP communication.
Use the TEST key, channel diagnostics, and load distribution checks during service and commissioning.

| Model | TLM8 Ethernet/IP |
| Protocol / output | Slave Ethernet/IP port plus RS485 Modbus RTU / Laumas ASCII |
| Load-cell channels | 8 independent channels |
| A/D converter | 8 channels - 24 bit (16000000 points) - 4.8 kHz |
| Display | Backlit graphic LCD, 60 x 32 mm, 128 x 64 pixels |
| Display range | 999999 |
| Approvals | OIML R 76:2006, class III, 10,000 divisions, 0.2 uV/VSI |
| Inputs / outputs | 3 logic inputs, 5 relay outputs |
| Mounting | Omega/DIN rail for back panel or junction box |
| Dimensions | 148 x 92 x 60 mm |
| Associated item codes | JOLLYTLM8ETHEIPN, JOLLYTLM8ETHEIPND, OEMTLM8ETHEIPN, OEMTLM8ETHEIPND, TLM8ETHEIP, TLM8ETHEIPN, TLM8ETHEIPND |
The TLM8 board mounts directly on an Omega/DIN rail inside your panel or junction box, or it can be supplied pre-installed in an IP-rated enclosure for field mounting.



This page represents the TLM8 Ethernet/IP protocol family. Related ordering codes can include display, enclosure, OEM, legal-for-trade, and accessory variations, so WeightechUSA should confirm the exact code before release to production.
Send the load-cell count, scale type, PLC protocol, enclosure requirement, power, and legal-for-trade target and we will confirm the correct TLM8 configuration.
Email SalesCall +1 (954) 666-0877 x 305| Number of divisions | ±999999 • 0.01 μV/d (with measurement range ±10 mV and sensitivity 2 mV/V) |
|---|---|
| Signal | Analog |
| Digital filter | 21 levels • 5÷600 Hz |
| Input power supply | 12÷24 VDC ±10%; 5 W |
| Internal Battery | -- |
| Storage temp range | -30 °C +80 °C |
| Manufacturer | Laumas |
| Number of load cells | up to 16 (350 Ω) - 4/6 wires • 5 VDC/240 mA |
| Fieldbus | Ethernet/IP |
| Linearity - Analog output linearity (only for TLB4) | <0.01% full scale • <0.01% full scale |
| Thermal Drift | Analog output thermal drift (only for TLB4) <0.0005% full scale/°C • <0.003% full scale/°C |
| A/D Converter | 8 channels - 24 bit (16000000 points) - 4.8 kHz |
| Display range | 999999 |
| Relay outputs | 5 relay outputs |
| Optoisolated digital inputs | 3 logic inputs |
| Serial ports | RS485 |
| Baud rate | Modbus RTU / Laumas ASCII via RS485 |
| Manufacturer's Part Number | TLM8-ETHET-IP |
| Certifications | OIML R 76:2006, class III, 10,000 divisions, 0.2 uV/VSI |
| Indicator_type | Weight transmitter |