YOUR STORE FOR LOAD CELLS, SCALE, WEIGHT INDICATORS.

Laumas W100 Weight Indicator with 0-10 VDC Weight-Reading Input

SKU
30505
$500.00
  • 30505 - Laumas W100 Weight Indicator with 0-10 VDC Weight-Reading Input
  • Type: Weight Indicator
  • Manufacturer: Laumas
  • Manufacturer part number(s): W100 + OPZWING010
  • Version: 0-10 VDC weight input
  • Relay outputs: 5; optoisolated digital inputs: 3
  • Serial ports: RS485, RS232 (Modbus RTU)
  • Display: 6-digit red LED, 14 mm; DIN box 96 x 48 x 130 mm, front panel mounting
  • Legal for trade: NTEP nmax 10000 Class III/IIIL; OIML R76:2006 class III 3x10000 divisions

Datasheet

OR
  • Description
  • Additional Information
  • 01 / 05Weight Indicator

    Laumas W100 weight indicator, 0-10 VDC weight input.

    The Laumas W100 is a DIN-box weight indicator for front panel mounting, with a 6-digit red LED display, RS485/RS232 serial ports (Modbus RTU) and one dedicated load cell input. This is the 0-10 VDC weight input version, Laumas order code W100 + OPZWING010: weight reading from 0-10 VDC input. It is supplied as a complete unit.

    6digits
    14 mm red LED display
    5
    Relay outputs (this version)
    3
    Optoisolated digital inputs
    10,000d
    NTEP nmax, Class III/IIIL
    02 / 05This version

    What this version includes.

    Adds weight reading from a 0-10 VDC input (15 kohm).

    Laumas order code(s)W100 + OPZWING010
    SKU30505
    Relay outputs5 - max 115 VAC/150 mA
    Optoisolated digital inputs3 - 5-24 VDC PNP

    Other combinations of options are available on request. The analog output and the additional RS485 port cannot be combined (datasheet: select one option among those marked with an asterisk).

    • RS485/RS232 serial ports for communication via Modbus RTU, ASCII Laumas or continuous one-way transmission protocols.
    • Five relay outputs controlled by the setpoint values or via protocols (four outputs if the analog output is present).
    • Three optoisolated PNP digital inputs: status reading via serial communication protocols (two inputs if the analog output is present).
    • 1 load cell dedicated input.
    • Weight reading from 0-10 VDC input, 15 kohm (option OPZWING010 built in).
    03 / 05Technical data

    Verified specifications for this version.

    ManufacturerLaumas
    Laumas order code(s) (MPN)W100 + OPZWING010
    SKU30505
    Version0-10 VDC weight input
    Power supply and consumption12-24 VDC +/-10%; 5 W
    Number of load cells / supplyup to 8 (350 ohm) - 4/6 wires - 5 VDC/120 mA (load cell input: 1, dedicated)
    A/D converter24 bit (16000000 points) - 4.8 kHz
    Conversions per second300/s
    Measurement range+/-39 mV
    Usable load cells sensitivity+/-7 mV/V
    Divisions (measurement range +/-10 mV, sensitivity 2 mV/V)+/-999999 - 0.01 uV/d
    Display range+/-999999
    Decimals / display increments0-4 - x1 x2 x5 x10 x20 x50 x100
    Digital filter / readings per second10 levels - 5-300 Hz
    Linearity<0.01% full scale
    Thermal drift<0.0005% full scale/degC
    Relay outputs5 - max 115 VAC/150 mA
    Optoisolated digital inputs3 - 5-24 VDC PNP
    Weight-reading input0-10 VDC (15 kohm)
    Serial portsRS485, RS232
    ProtocolsModbus RTU, ASCII Laumas, continuous one-way transmission
    Baud rate1200, 2400, 4800, 9600, 19200, 38400, 115200 (bit/s)
    Display6-digit semi-alphanumeric red LED, 14 mm height
    Signalling LEDs / keyboard8 signalling LEDs / 4-key keyboard
    Real-time clockClock/calendar with buffer battery
    EnclosureDIN box for front panel mounting, 96 x 48 x 130 mm (drilling template 92 x 45 mm)
    Front panel protectionIP54 (IP65 front optional with panel gasket OPZW48X96IP65)
    ConnectionsRemovable screw terminal blocks
    Humidity (condensate free)85%
    Storage temperature-30 degC +80 degC
    Working temperature-20 degC +60 degC
    UL Recognized component versionsrelay outputs 5 - max 30 VAC, 60 VDC/150 mA; working temperature -20 degC +50 degC; equipment to be powered by 12-24 VDC LPS or Class 2 power source
    Load cell connection (installation manual)6-wire load cell input; 4-wire load cells connect with jumpers between EX- and REF- and between EX+ and REF+
    Load cell capacity supplied (installation manual)up to eight 350 ohm or sixteen 700 ohm load cells
    Digital input functions (installation manual)NET/GROSS WEIGHT, SEMI-AUTOMATIC ZERO, PEAK, PRINT, LIMIT or REMOTE CONTROL
    04 / 05Features

    Display, hardware, main functions and legal-for-trade features.

    Description

    • Weight indicator in DIN box suitable for front panel mounting; dimensions 96 x 48 x 130 mm (drilling template 92 x 45 mm).
    • 6-digit semi-alphanumeric red LED display, 14 mm height.
    • 8 signalling LEDs and a 4-key keyboard.
    • IP54 front panel protection rating (IP65 front optional).
    • Real-time clock/calendar with buffer battery.
    • Removable screw terminal blocks.
    • 1 dedicated load cell input; up to 8 load cells (350 ohm) in parallel through a junction box.
    • Configured and managed with the free "Instrument Manager" PC software, downloadable from www.laumas.com.

    Main functions

    • Connections to: PLC via analog output (on request); PC/PLC via RS485/RS232 (up to 99 instruments with line repeaters, up to 32 without line repeaters); remote display and printer via RS485/RS232; up to 8 load cells in parallel by junction box; intelligent junction box or other multichannel instruments (digital equalization, load distribution analysis and automatic diagnostics); IoT gateway for cloud connection via RS485.
    • Digital filter to reduce the effects of weight oscillation.
    • Theoretical calibration (via keyboard) and real calibration (with sample weights and the possibility of weight linearization up to 8 points).
    • Tare weight zero setting; automatic zero setting at power-on; gross weight zero tracking; semi-automatic zero.
    • Semi-automatic tare (net/gross weight) and preset tare.
    • Displaying of the maximum weight value reached (peak).
    • Direct connection between RS485 and RS232 without converter.
    • Hysteresis and setpoint value setting.
    • Weight value printing with date and time via keyboard or external contact.
    • The indicator can be used as a remote display with setpoint.
    • 12 groups selection by 5 setpoint via external selector switch or contact (option on request).
    • Labeling machine management.

    Approved versions for legal for trade use

    • Approved versions for legal for trade use.
    • System parameters management protected by qualified access via software (password), hardware or fieldbus.
    • Weight subdivisions displaying (1/10 e).
    • Three operation modes: single interval, multiple range or multi-interval.
    • Net weight zero tracking.
    • Calibration.
    • Alibi memory (option on request, OPZWALIBI).
    • Values that can be printed via keyboard or external contact: gross weight, net weight, tare, preset tare, date, time, ID code (alibi memory).
    • On request: label support for initial verification.
    05 / 05Certifications

    Approvals and standards.

    Certifications

    • OIML R76:2006, class III, 3x10000 divisions, 0.2 uV/VSI / OIML R61 - WELMEC Guide 8.8:2011 (MID)
    • NTEP - nmax 10000 - Class III/IIIL - complies with United States regulations for legal for trade use
    • UL Recognized component - complies with United States and Canada regulations
    • Complies with the Eurasian Customs Union regulations
    • Equivalent of the CE marking for the United Kingdom
    • NMI Trade Approved - complies with Australian market regulations for legal for trade use
    • Complies with New Zealand regulations for legal for trade use
    • Complies with United Kingdom regulations for legal for trade use
    • Complies with the Brazilian regulations for legal for trade use
    • Complies with Chinese market regulations for legal for trade use

    Certifications on request

    • Conformity assessment (initial verification) in combination with a Laumas weighing module
    • Support for metric label (dimensions: 124x77x1.5 mm)
    • Complies with the regulations of the Russian Federation for legal for trade use

    Metrological data (type approved instruments)

    Metrological specifications of type approved instrumentsOIMLNTEPINMETRO
    Applied standards by regionEU: 2014/31/UE; OIML R76:2006; EN45501:2015. Russian Federation: GOST OIML R76-1-2011. United Kingdom: Non-automatic Weighing Instrument Regulations 2016. Australia: National Measurement Regulations 1999. New Zealand: Weights and Measures Regulations 1999. China: Law on Metrology of the People's Republic of ChinaUSA: NIST Handbook 44, 2020; NCWM Pub 14, 2021Brazil: Portaria Inmetro N 157/2022
    Operation modesingle interval, multi-interval, multiple rangesingle interval, multi-interval, multiple rangesingle interval, multi-interval, multiple range
    Accuracy classIII or IIIIIII or IIILIII
    Maximum number of scale verification divisions10000 (class III); 1000 (class IIII)10000 (class III/IIIL)10000 (class III)
    Minimum input signal for scale verification division0.2 uV/VSI-0.2 uV/VSI
    Working temperature-10 degC +40 degC-10 degC +40 degC (+14 degF +104 degF)-10 degC +40 degC
    Part number reference

    Order code.

    ProductOrder code
    Laumas W100 Weight Indicator with 0-10 VDC Weight-Reading Input30505

    Options on request (IP65 panel gasket, external 5-relay module, alibi memory, E/EC setpoint group selection and more) are listed on the Laumas W100 family page. Questions or a quote: 954-666-0877 x305 or [email protected].

    Talk to a WeightechUSA specialist.

    Send the model, the options you need and the application. We will confirm the Laumas order code and fit.

    Email SalesView DatasheetCall +1 (954) 666-0877 × 305