YOUR STORE FOR LOAD CELLS, SCALE, WEIGHT INDICATORS.

Laumas W100 Panel-Mount Weight Indicator

SKU
Laumas-W100
Select an option to see price $424.00
  • Laumas-W100 - Laumas W100 Panel-Mount Weight Indicator
  • Type: Weight Indicator
  • Manufacturer: Laumas
  • DIN box for front panel mounting, 96 x 48 x 130 mm; 6-digit red LED display, 14 mm
  • RS485/RS232 serial ports (Modbus RTU); one dedicated load cell input
  • Legal for trade: NTEP nmax 10000 Class III/IIIL; OIML R76:2006 class III 3x10000 divisions
  • Available in five versions. See the table below for each SKU and order code. Other option combinations on request.

Datasheet

OR
  • Description
  • Additional Information
  • 01 / 06Weight Indicator

    Laumas W100 weight indicator family.

    The Laumas W100 is a DIN-box weight indicator for front panel mounting with a 6-digit red LED display, RS485/RS232 serial ports (Modbus RTU, ASCII Laumas or continuous one-way transmission), five relay outputs, three optoisolated digital inputs and one dedicated load cell input. Approved versions are available for legal for trade use (NTEP nmax 10000 Class III/IIIL; OIML R76:2006 class III). It is available as five complete versions; use the table below to select the SKU your application requires. Other combinations of options are available on request.

    6digits
    14 mm red LED display
    5
    Versions (complete units)
    10,000d
    NTEP nmax, Class III/IIIL
    300/s
    Conversions per second
    02 / 06Versions

    Available versions and order codes.

    Each version is a complete unit. The analog output and the additional RS485 port cannot be combined (datasheet: select one option among those marked with an asterisk). Relay outputs and digital inputs: one input and one output are not available on the analog-output and additional-RS485 versions.

    VersionLaumas order code(s) (MPN)SKUWhat it addsRelay outputsDigital inputsPrice
    RS485/RS232 (base)W100Base unit: RS485 and RS232 serial ports (Modbus RTU, ASCII Laumas, continuous one-way transmission).53$424.00
    Analog output (16 bit)W100 + OPZW1ANALOGICAAdds an optoisolated 16 bit analog output (current or voltage). One input and one output are not available.42$522.00
    Additional RS485 portW100 + OPZW1RS485Adds an additional RS485 port. One input and one output are not available.42$522.00
    0-10 VDC weight inputW100 + OPZWING010Adds weight reading from a 0-10 VDC input (15 kohm).53$500.00
    4-20 mA weight inputW100 + OPZWING420Adds weight reading from a 4-20 mA input (120 ohm).53$500.00
    03 / 06Technical data

    Specifications common to all versions.

    Values that differ per version (relay outputs, digital inputs, serial ports, analog output, weight-reading input) are listed in the table above and on each version's own page.

    Power supply and consumption12-24 VDC +/-10%; 5 W
    Number of load cells / supplyup to 8 (350 ohm) - 4/6 wires - 5 VDC/120 mA (load cell input: 1, dedicated)
    A/D converter24 bit (16000000 points) - 4.8 kHz
    Conversions per second300/s
    Measurement range+/-39 mV
    Usable load cells sensitivity+/-7 mV/V
    Divisions (measurement range +/-10 mV, sensitivity 2 mV/V)+/-999999 - 0.01 uV/d
    Display range+/-999999
    Decimals / display increments0-4 - x1 x2 x5 x10 x20 x50 x100
    Digital filter / readings per second10 levels - 5-300 Hz
    Linearity<0.01% full scale
    Thermal drift<0.0005% full scale/degC
    Analog output linearity (analog output version)<0.01% full scale
    Analog output thermal drift (analog output version)<0.003% full scale/degC
    Relay outputs5 (4 with the analog output or the additional RS485 port) - max 115 VAC/150 mA
    Optoisolated digital inputs3 (2 with the analog output or the additional RS485 port) - 5-24 VDC PNP
    Serial portsRS485, RS232
    ProtocolsModbus RTU, ASCII Laumas, continuous one-way transmission
    Baud rate1200, 2400, 4800, 9600, 19200, 38400, 115200 (bit/s)
    Display6-digit semi-alphanumeric red LED, 14 mm height
    Signalling LEDs / keyboard8 signalling LEDs / 4-key keyboard
    Real-time clockClock/calendar with buffer battery
    EnclosureDIN box for front panel mounting, 96 x 48 x 130 mm (drilling template 92 x 45 mm)
    Front panel protectionIP54 (IP65 front optional with panel gasket OPZW48X96IP65)
    ConnectionsRemovable screw terminal blocks
    Humidity (condensate free)85%
    Storage temperature-30 degC +80 degC
    Working temperature-20 degC +60 degC
    UL Recognized component versionsrelay outputs 5/4 - max 30 VAC, 60 VDC/150 mA; working temperature -20 degC +50 degC; equipment to be powered by 12-24 VDC LPS or Class 2 power source
    Load cell connection (installation manual)6-wire load cell input; 4-wire load cells connect with jumpers between EX- and REF- and between EX+ and REF+
    Load cell capacity supplied (installation manual)up to eight 350 ohm or sixteen 700 ohm load cells
    Digital input functions (installation manual)NET/GROSS WEIGHT, SEMI-AUTOMATIC ZERO, PEAK, PRINT, LIMIT or REMOTE CONTROL
    04 / 06Features

    Display, hardware, main functions and legal-for-trade features.

    Description

    • Weight indicator in DIN box suitable for front panel mounting; dimensions 96 x 48 x 130 mm (drilling template 92 x 45 mm).
    • 6-digit semi-alphanumeric red LED display, 14 mm height.
    • 8 signalling LEDs and a 4-key keyboard.
    • IP54 front panel protection rating (IP65 front optional).
    • Real-time clock/calendar with buffer battery.
    • Removable screw terminal blocks.
    • 1 dedicated load cell input; up to 8 load cells (350 ohm) in parallel through a junction box.
    • Configured and managed with the free "Instrument Manager" PC software, downloadable from www.laumas.com.

    Inputs/outputs and communication

    • RS485/RS232 serial ports for communication via Modbus RTU, ASCII Laumas or continuous one-way transmission protocols.
    • Five relay outputs controlled by the setpoint values or via protocols (four outputs if the analog output is present).
    • Three optoisolated PNP digital inputs: status reading via serial communication protocols (two inputs if the analog output is present).
    • 1 load cell dedicated input.
    • Current or voltage 16 bit optoisolated analog output (option on request).

    Main functions

    • Connections to: PLC via analog output (on request); PC/PLC via RS485/RS232 (up to 99 instruments with line repeaters, up to 32 without line repeaters); remote display and printer via RS485/RS232; up to 8 load cells in parallel by junction box; intelligent junction box or other multichannel instruments (digital equalization, load distribution analysis and automatic diagnostics); IoT gateway for cloud connection via RS485.
    • Digital filter to reduce the effects of weight oscillation.
    • Theoretical calibration (via keyboard) and real calibration (with sample weights and the possibility of weight linearization up to 8 points).
    • Tare weight zero setting; automatic zero setting at power-on; gross weight zero tracking; semi-automatic zero.
    • Semi-automatic tare (net/gross weight) and preset tare.
    • Displaying of the maximum weight value reached (peak).
    • Direct connection between RS485 and RS232 without converter.
    • Hysteresis and setpoint value setting.
    • Weight value printing with date and time via keyboard or external contact.
    • The indicator can be used as a remote display with setpoint.
    • 12 groups selection by 5 setpoint via external selector switch or contact (option on request).
    • Labeling machine management.

    Approved versions for legal for trade use

    • Approved versions for legal for trade use.
    • System parameters management protected by qualified access via software (password), hardware or fieldbus.
    • Weight subdivisions displaying (1/10 e).
    • Three operation modes: single interval, multiple range or multi-interval.
    • Net weight zero tracking.
    • Calibration.
    • Alibi memory (option on request, OPZWALIBI).
    • Values that can be printed via keyboard or external contact: gross weight, net weight, tare, preset tare, date, time, ID code (alibi memory).
    • On request: label support for initial verification.
    05 / 06Certifications

    Approvals and standards.

    Certifications

    • OIML R76:2006, class III, 3x10000 divisions, 0.2 uV/VSI / OIML R61 - WELMEC Guide 8.8:2011 (MID)
    • NTEP - nmax 10000 - Class III/IIIL - complies with United States regulations for legal for trade use
    • UL Recognized component - complies with United States and Canada regulations
    • Complies with the Eurasian Customs Union regulations
    • Equivalent of the CE marking for the United Kingdom
    • NMI Trade Approved - complies with Australian market regulations for legal for trade use
    • Complies with New Zealand regulations for legal for trade use
    • Complies with United Kingdom regulations for legal for trade use
    • Complies with the Brazilian regulations for legal for trade use
    • Complies with Chinese market regulations for legal for trade use

    Certifications on request

    • Conformity assessment (initial verification) in combination with a Laumas weighing module
    • Support for metric label (dimensions: 124x77x1.5 mm)
    • Complies with the regulations of the Russian Federation for legal for trade use

    Metrological data (type approved instruments)

    Metrological specifications of type approved instrumentsOIMLNTEPINMETRO
    Applied standards by regionEU: 2014/31/UE; OIML R76:2006; EN45501:2015. Russian Federation: GOST OIML R76-1-2011. United Kingdom: Non-automatic Weighing Instrument Regulations 2016. Australia: National Measurement Regulations 1999. New Zealand: Weights and Measures Regulations 1999. China: Law on Metrology of the People's Republic of ChinaUSA: NIST Handbook 44, 2020; NCWM Pub 14, 2021Brazil: Portaria Inmetro N 157/2022
    Operation modesingle interval, multi-interval, multiple rangesingle interval, multi-interval, multiple rangesingle interval, multi-interval, multiple range
    Accuracy classIII or IIIIIII or IIILIII
    Maximum number of scale verification divisions10000 (class III); 1000 (class IIII)10000 (class III/IIIL)10000 (class III)
    Minimum input signal for scale verification division0.2 uV/VSI-0.2 uV/VSI
    Working temperature-10 degC +40 degC-10 degC +40 degC (+14 degF +104 degF)-10 degC +40 degC
    06 / 06Options on request

    Options and accessories (no SKU, quoted on request).

    These options are quoted on request and are not sold as separate SKUs on this page. Other combinations of options are available on request. Options marked with an asterisk (*) belong to a group from which the datasheet says to select one option only.

    OptionLaumas codeGroupNotes
    Label support for initial verificationno order code printedAccessoryDatasheet: "On request: label support for initial verification". A support for a metric label (124x77x1.5 mm) is listed under certifications on request.
    IP65 panel gasketOPZW48X96IP65AccessoryGives the IP65 front protection (standard front is IP54).
    Stainless steel adjustable bracket for wall and table mountingno order code printedAccessoryListed on the laumas.com datasheet and price list, without an order code.
    Optoisolated 16 bit analog outputOPZW1ANALOGICA *InterfaceOne input and one output not available (4 relay outputs and 2 digital inputs remain). Select one option among those marked with an asterisk: mutually exclusive with OPZW1RS485. Supplied as a complete unit under SKU 30503.
    Additional RS485 portOPZW1RS485 *InterfaceOne input and one output not available (4 relay outputs and 2 digital inputs remain). Select one option among those marked with an asterisk: mutually exclusive with OPZW1ANALOGICA. Supplied as a complete unit under SKU 30504.
    Weight reading from 0-10 VDC input (15 kohm)OPZWING010InterfaceSupplied as a complete unit under SKU 30505.
    Weight reading from 4-20 mA input (120 ohm)OPZWING420InterfaceSupplied as a complete unit under SKU 30506.
    12 groups selection by 5 setpoint via external selector switchEC *ExpansionSelect one option among those marked with an asterisk: mutually exclusive with option E.
    12 groups selection by 5 setpoint via external contactE *ExpansionSelect one option among those marked with an asterisk: mutually exclusive with option EC.
    Simultaneous use of the E/EC option with the analog outputOPZWAECExpansionNeeded to combine E or EC with the analog output.
    External 5-relay module to increase the capacity of SPDT contacts to 115 VAC/2 ARELE5MExpansion
    Alibi memoryOPZWALIBIApplications - software

    Talk to a WeightechUSA specialist.

    Send the model, the options you need and the application. We will confirm the Laumas order code and fit.

    Email SalesView DatasheetCall +1 (954) 666-0877 × 305