YOUR STORE FOR LOAD CELLS, SCALE, WEIGHT INDICATORS.

Schenck Process RTN 0.05-33t D724754.04 Ring Torsion Load Cell

SKU
15401
$1,534.00
  • 15401 - Schenck Process RTN 0.05-33t D724754.04 Ring Torsion Load Cell
  • Type: Compression, canister, rocker column, and ring torsion load cells
  • Manufacturer part number: D724754.04
  • Capacity: 33 t
  • Material: Stainless steel
  • Protection: IP68 (tested 100 h at 1 m water column)
  • Signal: Analog
  • Manufacturer: Schenck Process
  • Cable length: 15 m
  • Cable type: 4-wire cable

Datasheet

OR
  • Description
  • Additional Information
  • 01 / 07Compression, canister, rocker column, and ring torsion load cells

    Compression, canister, rocker column, and ring torsion load cells for confirmed-fit replacement and scale builds.

    The Schenck Process RTN 0.05-33t D724754.04 Ring Torsion Load Cell is a compression, canister, rocker column, or ring torsion load cell rated 33 t. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Schenck Process and the model / part number as D724754.04.

    33 t
    Rated capacity
    Stainless steel
    Material
    IP68 (tested 100 h at 1 m water column)
    Protection
    Analog
    Signal
    02 / 07Application fit

    Where this load cell belongs.

    Compression cells cover canister, rocker-column, ring-torsion, and disk-style weighing for tanks, silos, truck scales, and high-capacity systems.

    01

    Truck and tank scales

    Compression geometry is common in high-capacity vehicle and vessel weighing.

    compression
    02

    Outdoor and washdown service

    Material and seal rating matter because compression cells often live under structures.

    environment
    03

    Mount-dependent accuracy

    Cup, mount, lift-off, and side-load details must be confirmed with the cell.

    mount
    03 / 07Mechanical and electrical fit

    Confirm the details before replacement.

    CAPACITY

    Capacity and load path

    Confirm 33 t against dead load, live load, impact, and load distribution.

    MECHANICAL

    Mechanical fit

    Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.

    ENVIRONMENT

    Environment

    Catalog protection is IP68 (tested 100 h at 1 m water column). Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.

    ELECTRICAL

    Electrical match

    Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.

    04 / 07Installation notes

    A load cell is only correct when the assembly around it is correct.

    The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.

    • Match mounting holes, load point, thread, and installed height
    • Confirm cell count and junction-box wiring
    • Confirm material and protection rating for the environment
    • Confirm rated output, excitation, and input/output impedance
    • Keep datasheets, photos, and old part numbers with the service record
    05 / 07Dimensions and connections

    Use the available images to confirm the mechanical envelope and cable connection.

    Schenck Process RTN 0.05-33t D724754.04 Ring Torsion Load Cell dimension reference image
    Dimension reference
    06 / 07Technical data

    Catalog attributes for this load cell.

    MaterialStainless steel
    ProtectionIP68 (tested 100 h at 1 m water column)
    SignalAnalog
    Cable length15 m
    Cable type4-wire cable
    ManufacturerSchenck Process
    Manufacturer part numberD724754.04
    Rated capacity33 t
    Capacity weight33 t
    Accuracy0.05
    DimensionsA=95 mm; B=40 mm; C=95 mm; D=—; H=65 mm; K=10 mm
    Rated output2.85 mV/V
    Rated output tolerance±2.85 µV/V
    Recommended excitation5 VDC (rated 5 … 30 V)
    Maximum excitation60 V
    Input impedance4450 ± 100 Ω
    Output impedance4010 ± 2 Ω
    Insulation resistance> 20 GΩ
    Combined error0.05%
    Creep error± 0.03 % Cn / 30 min
    Safe overload58 t
    Ultimate overload130 t
    Operating temperature−30 to +80 °C
    Cable fittingBrass, nickel-plated / sealing CR/NBR
    Non-linearity± 0.05 % Cn
    Hysteresis± 0.05 % Cn
    Compensated temperature−10 to +40 °C
    Storage temperature−50 to +85 °C
    07 / 07Part number reference

    Order code and fit FAQ.

    ProductOrder code
    Schenck Process RTN 0.05-33t D724754.04 Ring Torsion Load Cell15401

    Is the SKU enough to confirm replacement?

    No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.

    What if some catalog attributes are blank?

    Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.

    Can WeightechUSA help identify a match?

    Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.

    Talk to a WeightechUSA load-cell specialist.

    Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 15401 is the right fit.

    Email SalesView DatasheetCall +1 (954) 666-0877 × 305