The Model 1042 is a low profile single-point load cell designed for direct mounting in weighing platforms. Its small physical size, combined with high accuracy and low cost, makes this load cell ideally suited for retail, bench and counting scales.
Capacities of 5kg and above are supplied as standard in anodized aluminum. This high accuracy load cell is approved to NTEP and other stringent approval standards, including OIML R60. A humidity resistant protective coating assures long term stability over the entire compensated temperature range.
The two additional sense wires feed back the voltage reaching the load cell. Complete compensation of changes in lead resistance due to temperature change and/or cable extenstion, is achieved by feeding this voltage into the appropriate electronics.
Load Cell 1042 OPTIONAL
Load Cell 1042 APPLICATIONS
Approval | ATEX, FM, NTEP, OIML |
---|---|
Signal | Analog |
Protection class | IP66 |
Material | Aluminum |
Internal Battery | -- |
Maximum excitation | 15 VDC or VAC RMS |
Maximum safe overload | 150 % of R.C. |
Max platform size | - |
Operating temp range | -20 to -70 C |
Recommended excitation | 10 VDC or VAC RMS |
Recommended torque | Up to 30 kg; 7.0, 35 kg and above: 10.0 |
Sensitivity | 2.0 mV/V |
Storage temp range | - |
Manufacturer | Vishay-Tedea |
Cable type | 6 wire, PVC, single floating screen |
Cable length | 1 m |
Interchangeable | Artech 879, Cardinal TSP, CAS BCA, Flintec PC 42, Revere 642, Rice Lake RL1042, Rice Lake RLSP4, Scaime AG, Coti CG-42, HBM SP4 |