YOUR STORE FOR LOAD CELLS, SCALE, WEIGHT INDICATORS.

Tedea-Huntleigh 380-75kg 00380-075K-C3-00X Single Point Load Cell
Tedea-Huntleigh · Load cell

380-75kg 00380-075K-C3-00X Single Point Load Cell

SKU 11315
IP65; Aluminum; Analog signal; OIML R60 C3; 4.9 ft / 1.5 m cable
81.00
$81.00
  • 11315 - Tedea-Huntleigh 380-75kg 00380-075K-C3-00X Single Point Load Cell
  • Type: Single point load cells
  • Manufacturer part number: 00380-075K-C3-00X
  • Capacity: 75 kg
  • Material: Aluminium (RTV potting)
  • Protection: IP65
  • Signal: Analog
  • Manufacturer: Tedea-Huntleigh
  • Cable length: 4.9 ft / 1.5 m

Datasheet

OR
  • Description
  • Additional Information
  • 01 / 06Single point load cells

    Single point load cells for confirmed-fit replacement and scale builds.

    The Tedea-Huntleigh 380-75kg 00380-075K-C3-00X Single Point Load Cell is a single point load cell rated 75 kg. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Tedea-Huntleigh and the model / part number as 00380-075K-C3-00X.

    75 kg
    Rated capacity
    Aluminium (RTV potting)
    Material
    IP65
    Protection
    Analog
    Signal
    02 / 06Application fit

    Where this load cell belongs.

    Single point cells are selected around platform size, off-center loading behavior, capacity, material, and approval requirements.

    01

    Bench and retail platforms

    Best fit for compact scales where one cell supports the full platform.

    platform
    02

    Counting and pricing scales

    A common choice for small weighing stations that need repeatability under off-center loading.

    bench scale
    03

    Replacement work

    Confirm maximum platform size and mounting pattern before replacing another brand.

    retrofit
    03 / 06Mechanical and electrical fit

    Confirm the details before replacement.

    CAPACITY

    Capacity and load path

    Confirm 75 kg against dead load, live load, impact, and load distribution.

    MECHANICAL

    Mechanical fit

    Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.

    ENVIRONMENT

    Environment

    Catalog protection is IP65. Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.

    ELECTRICAL

    Electrical match

    Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.

    04 / 06Installation notes

    A load cell is only correct when the assembly around it is correct.

    The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.

    • Match mounting holes, load point, thread, and installed height
    • Confirm cell count and junction-box wiring
    • Confirm material and protection rating for the environment
    • Confirm rated output, excitation, and input/output impedance
    • Keep datasheets, photos, and old part numbers with the service record
    05 / 06Technical data

    Catalog attributes for this load cell.

    MaterialAluminium (RTV potting)
    ProtectionIP65
    SignalAnalog
    Cable length4.9 ft / 1.5 m
    ManufacturerTedea-Huntleigh
    Manufacturer part number00380-075K-C3-00X
    Rated capacity75 kg
    Capacity weight75 kg
    SealingPotted
    ApprovalOIML C3/C4
    ThreadThrough Hole
    Rated output1.0 mV/V
    Input impedance1160 ± 15 Ω
    Output impedance1000 ± 10 Ω
    Insulation resistance5000 MΩ
    Creep error≤ ±0.024 % / 30 min (G4/C3)
    Safe overload300 %RC
    Ultimate overload400 %RC
    Operating temperature−30 to +70 °C
    Number of wires4
    Output sensitivity1.0 mV/V
    Zero balance± 0.10 mV/V
    Compensated temperature−10 to +40 °C
    06 / 06Part number reference

    Order code and fit FAQ.

    ProductOrder code
    Tedea-Huntleigh 380-75kg 00380-075K-C3-00X Single Point Load Cell11315

    Is the SKU enough to confirm replacement?

    No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.

    What if some catalog attributes are blank?

    Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.

    Can WeightechUSA help identify a match?

    Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.

    DIMENSIONS

    Outline dimensions.

    Tedea-Huntleigh 380-75kg 00380-075K-C3-00X Single Point Load Cell dimensions drawing
    Source: manufacturer datasheet

    Talk to a WeightechUSA load-cell specialist.

    Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 11315 is the right fit.

    Email SalesView DatasheetCall +1 (954) 666-0877 × 305