RLC-10t Compression Load CellRevere RLC-10t 00RLC-010T-D3-00N Compression Load Cell
- Description
- Additional Information
- 01 / 06Compression, canister, rocker column, and ring torsion load cells
Compression, canister, rocker column, and ring torsion load cells for confirmed-fit replacement and scale builds.
The Revere RLC-10t 00RLC-010T-D3-00N Compression Load Cell is a compression, canister, rocker column, or ring torsion load cell rated 10 t. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Vishay-Revere and the model / part number as 00RLC-010T-D3-00N.
10 tRated capacityStainless steel 1.4542MaterialIP66 and IP68 (IP69K on 250 kg / 5 t / 10 t)ProtectionAnalogSignal02 / 06Application fitWhere this load cell belongs.
Compression cells cover canister, rocker-column, ring-torsion, and disk-style weighing for tanks, silos, truck scales, and high-capacity systems.
01Truck and tank scales
Compression geometry is common in high-capacity vehicle and vessel weighing.
compression02Outdoor and washdown service
Material and seal rating matter because compression cells often live under structures.
environment03Mount-dependent accuracy
Cup, mount, lift-off, and side-load details must be confirmed with the cell.
mount03 / 06Mechanical and electrical fitConfirm the details before replacement.
CAPACITYCapacity and load path
Confirm 10 t against dead load, live load, impact, and load distribution.
MECHANICALMechanical fit
Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.
ENVIRONMENTEnvironment
Catalog protection is IP66 and IP68 (IP69K on 250 kg / 5 t / 10 t). Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.
ELECTRICALElectrical match
Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.
04 / 06Installation notesA load cell is only correct when the assembly around it is correct.
The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.
- Match mounting holes, load point, thread, and installed height
- Confirm cell count and junction-box wiring
- Confirm material and protection rating for the environment
- Confirm rated output, excitation, and input/output impedance
- Keep datasheets, photos, and old part numbers with the service record
05 / 06Technical dataCatalog attributes for this load cell.
Material Stainless steel 1.4542 Protection IP66 and IP68 (IP69K on 250 kg / 5 t / 10 t) Signal Analog Cable length 16.4 ft / 5 m Manufacturer Vishay-Revere Manufacturer part number 00RLC-010T-D3-00N Rated capacity 10 t Capacity weight 10 t Sealing Welded Seal Approval OIML R60 C3 (to C6) · NTEP Class IIIL Rated output 2 mV/V (1.75 for 0.25 t, 2.05 for 10 t) Recommended excitation 5 to 15 V Maximum excitation 30 V Input impedance 1110 ± 50 Ω Output impedance 1025 ± 25 Ω Insulation resistance ≥ 5000 MΩ Combined error ≤ ±0.0230 %FSO (C3) Creep error ≤ ±0.0245 % / 30 min (C3) Safe overload 150 %Emax Ultimate overload 300 %Emax Operating temperature −30 to +70 °C Output sensitivity 2 mV/V (1.75 for 0.25 t, 2.05 for 10 t) Zero balance ± 1.0 %FSO Compensated temperature −10 to +40 °C Safe side load 100 %Emax (50 % for 28 & 60 t) 06 / 06Part number referenceOrder code and fit FAQ.
Product Order code Revere RLC-10t 00RLC-010T-D3-00N Compression Load Cell 12095 Is the SKU enough to confirm replacement?
No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.
What if some catalog attributes are blank?
Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.
Can WeightechUSA help identify a match?
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.
DIMENSIONSOutline dimensions.

Source: manufacturer datasheet Talk to a WeightechUSA load-cell specialist.
Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 12095 is the right fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305 Signal Analog Protection class IP68 Material Stainless Steel Combined error ≤ ±0.0230 %FSO (C3) Compensated temp range −10 to +40 °C Creep error 20mins ≤ ±0.0245 % / 30 min (C3) Input impedance 1110 ± 50 Ω Insulation resistance ≥ 5000 MΩ Internal Battery -- Maximum excitation 30 V Maximum safe overload 150 %Emax Operating temp range −30 to +70 °C Output impedance 1025 ± 25 Ω Rated capacity 10 t Rated output 2 mV/V (1.75 for 0.25 t, 2.05 for 10 t) Recommended excitation 5 to 15 V Safe sideload 100 %Emax (50 % for 28 & 60 t) Ultimate central overload 300 %Emax Zero balance ± 1.0 %FSO Manufacturer Vishay-Revere Cable length 16.4 ft / 5 m Sealing Welded Seal Manufacturer's Part Number 00RLC-010T-D3-00N Approval OIML R60 C3 Short name RLC-10t Compression Load Cell Hero chips IP68; Stainless Steel; Analog signal; OIML R60 C3; 16.4 ft / 5 m cable