5103-50Klb Double-Ended BeamRevere 5103-50Klb 05103-050E-B1-01X Double-Ended Beam Load Cell
- Description
- Additional Information
- 01 / 06Double-ended beam and weighbridge load cells
Double-ended beam and weighbridge load cells for confirmed-fit replacement and scale builds.
The Revere 5103-50Klb 05103-050E-B1-01X Double-Ended Beam Load Cell is a double-ended beam load cell rated 50K lb. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Vishay-Revere and the model / part number as 05103-050E-B1-01X.
50K lbRated capacityNickel-plated alloy steelMaterialIP67ProtectionAnalogSignal02 / 06Application fitWhere this load cell belongs.
Double-ended beam cells are commonly used in truck scales, rail scales, hoppers, and other heavy multi-cell systems.
01Truck and rail scales
A strong fit for weighbridges and vehicle-scale load points.
weighbridge02Heavy vessels
Works in silo, hopper, and tank weighing when the mount controls load introduction.
vessel03Service replacement
Confirm cups, links, mounts, and cable exit before ordering.
retrofit03 / 06Mechanical and electrical fitConfirm the details before replacement.
CAPACITYCapacity and load path
Confirm 50K lb against dead load, live load, impact, and load distribution.
MECHANICALMechanical fit
Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.
ENVIRONMENTEnvironment
Catalog protection is IP67. Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.
ELECTRICALElectrical match
Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.
04 / 06Installation notesA load cell is only correct when the assembly around it is correct.
The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.
- Match mounting holes, load point, thread, and installed height
- Confirm cell count and junction-box wiring
- Confirm material and protection rating for the environment
- Confirm rated output, excitation, and input/output impedance
- Keep datasheets, photos, and old part numbers with the service record
05 / 06Technical dataCatalog attributes for this load cell.
Material Nickel-plated alloy steel Protection IP67 Signal Analog Cable length 29.5 ft / 9 m Manufacturer Vishay-Revere Manufacturer part number 05103-050E-B1-01X Rated capacity 50K lb Capacity in pounds 50,000 lb Sealing Covered and Potted Approval OIML R60 C3 · NTEP Class IIIL/10000 Thread Through Hole Rated output 3.0 mV/V Recommended excitation 5 to 12 V Maximum excitation 15 V Input impedance 700 ± 7 Ω Output impedance 700 ± 7 Ω Insulation resistance ≥ 5000 MΩ Combined error ≤ ±0.0200 %FSO (C3) Non-repeatability ≤ ±0.0100 %FSO Creep error ≤ ±0.0245 % / 30 min (C3) Safe overload 150 %Emax Ultimate overload 300 %Emax Operating temperature −40 to +80 °C Output sensitivity 3.0 mV/V Zero balance ± 1.0 %FSO Compensated temperature −10 to +40 °C Safe side load 100 %Emax 06 / 06Part number referenceOrder code and fit FAQ.
Product Order code Revere 5103-50Klb 05103-050E-B1-01X Double-Ended Beam Load Cell 12297 Is the SKU enough to confirm replacement?
No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.
What if some catalog attributes are blank?
Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.
Can WeightechUSA help identify a match?
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.
DIMENSIONSOutline dimensions.

Source: manufacturer datasheet Talk to a WeightechUSA load-cell specialist.
Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 12297 is the right fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305 Signal Analog Protection class IP67 Material Nickel-Plated Alloy Steel Combined error ≤ ±0.0200 %FSO (C3) Compensated temp range −10 to +40 °C Creep error 20mins ≤ ±0.0245 % / 30 min (C3) Input impedance 700 ± 7 Ω Insulation resistance ≥ 5000 MΩ Internal Battery -- Maximum excitation 15 V Maximum safe overload 150 %Emax Non-repeatability ≤ ±0.0100 %FSO NTEP/OIML NTEP Operating temp range −40 to +80 °C Output impedance 700 ± 7 Ω Rated capacity 50K lb Rated output 3.0 mV/V Recommended excitation 5 to 12 V Safe sideload 100 %Emax Ultimate central overload 300 %Emax Zero balance ± 1.0 %FSO Manufacturer Vishay-Revere Cable length 29.5 ft / 9 m Thread - Clevis Through Hole Sealing Covered and Potted Interchangeable Zemic H9C Manufacturer's Part Number 05103-050E-B1-01X Approval OIML R60 C3 Short name 5103-50Klb Double-Ended Beam Hero chips IP67; Nickel-Plated Alloy Steel; Analog signal; OIML R60 C3; 29.5 ft / 9 m cable