The Revere 9102-1Klb 09102-001E-A5-00X Single Point Load Cell is a single point load cell rated 1K lb. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Vishay-Revere and the model / part number as 09102-001E-A5-00X.
Single point cells are selected around platform size, off-center loading behavior, capacity, material, and approval requirements.
Best fit for compact scales where one cell supports the full platform.
A common choice for small weighing stations that need repeatability under off-center loading.
Confirm maximum platform size and mounting pattern before replacing another brand.
Confirm 1K lb against dead load, live load, impact, and load distribution.
Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.
Catalog protection is IP66 and IP68. Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.
Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.
The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.
| Material | Stainless steel 1.4542 |
| Protection | IP66 and IP68 |
| Signal | Analog |
| Manufacturer | Vishay-Revere |
| Manufacturer part number | 09102-001E-A5-00X |
| Rated capacity | 1K lb |
| Capacity | 1000 lb |
| Capacity in pounds | 1,000 lb |
| Sealing | Welded Seal |
| Approval | OIML R60 C3/C5 · NTEP Class III |
| Thread | Through Hole |
| Rated output | 2 mV/V |
| Recommended excitation | 5 to 12 V |
| Maximum excitation | 15 V |
| Input impedance | 350 ± 3.5 Ω |
| Output impedance | 350 ± 3.5 Ω |
| Insulation resistance | > 5000 MΩ |
| Combined error | ≤ ±0.0200 %FSO (C3) |
| Non-repeatability | ≤ ±0.0100 %FSO |
| Creep error | ≤ ±0.0245 % / 30 min (C3) |
| Safe overload | 150 %Emax |
| Ultimate overload | 300 %Emax |
| Operating temperature | −40 to +80 °C |
| Output sensitivity | 2 mV/V |
| Zero balance | ± 1.0 %FSO |
| Compensated temperature | −10 to +40 °C |
| Safe side load | 100 %Emax (50 % for 200 lb) |
| Product | Order code |
|---|---|
| Revere 9102-1Klb 09102-001E-A5-00X Single Point Load Cell | 12344 |
No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.
Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.

Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 12344 is the right fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305| Signal | Analog |
|---|---|
| Protection class | IP68 |
| Material | Stainless Steel |
| Combined error | ≤ ±0.0200 %FSO (C3) |
| Compensated temp range | −10 to +40 °C |
| Creep error 20mins | ≤ ±0.0245 % / 30 min (C3) |
| Input impedance | 350 ± 3.5 Ω |
| Insulation resistance | > 5000 MΩ |
| Internal Battery | -- |
| Maximum excitation | 15 V |
| Maximum safe overload | 150 %Emax |
| Non-repeatability | ≤ ±0.0100 %FSO |
| NTEP/OIML | NTEP |
| Operating temp range | −40 to +80 °C |
| Output impedance | 350 ± 3.5 Ω |
| Rated capacity | 1K lb |
| Rated output | 2 mV/V |
| Recommended excitation | 5 to 12 V |
| Safe sideload | 100 %Emax (50 % for 200 lb) |
| Ultimate central overload | 300 %Emax |
| Zero balance | ± 1.0 %FSO |
| Manufacturer | Vishay-Revere |
| Capacity | 1000 lb |
| Thread - Clevis | Through Hole |
| Sealing | Welded Seal |
| Manufacturer's Part Number | 09102-001E-A5-00X |
| Approval | OIML R60 C3 |
| Short name | 9102-1Klb Single Point Load Cell |
| Hero chips | 1,000 lb; IP68; Stainless Steel; Analog signal; OIML R60 C3 |