Zemic H9N-125000lb H9N-N10-125K-9B Double-Ended Beam Load Cell
- Description
- Additional Information
- 01 / 07Double-ended beam and weighbridge load cells
Double-ended beam and weighbridge load cells for confirmed-fit replacement and scale builds.
The Zemic H9N-125000lb H9N-N10-125K-9B Double-Ended Beam Load Cell is a double-ended beam load cell rated 125000 lb. Use it as a replacement or new-build component only after confirming capacity, dimensions, material, seal rating, electrical signal, and wiring against the scale assembly. The catalog identifies the manufacturer as Zemic and the model / part number as H9N-N10-125K-9B.
125000 lbRated capacityAlloy steelMaterialIP67ProtectionAnalogSignal02 / 07Application fitWhere this load cell belongs.
Double-ended beam cells are commonly used in truck scales, rail scales, hoppers, and other heavy multi-cell systems.
01Truck and rail scales
A strong fit for weighbridges and vehicle-scale load points.
weighbridge02Heavy vessels
Works in silo, hopper, and tank weighing when the mount controls load introduction.
vessel03Service replacement
Confirm cups, links, mounts, and cable exit before ordering.
retrofit03 / 07Mechanical and electrical fitConfirm the details before replacement.
CAPACITYCapacity and load path
Confirm 125000 lb against dead load, live load, impact, and load distribution.
MECHANICALMechanical fit
Check mounting pattern, installed height, load point, cable exit, and platform or vessel geometry before ordering.
ENVIRONMENTEnvironment
Catalog protection is IP67. Verify washdown, outdoor, corrosive, or hazardous exposure before replacement.
ELECTRICALElectrical match
Catalog signal is Analog. Confirm excitation, mV/V output, impedance, wiring color code, and indicator/transmitter input.
04 / 07Installation notesA load cell is only correct when the assembly around it is correct.
The safest way to quote or replace a load cell is to verify the installed geometry and the electrical interface together. Capacity alone is not enough.
- Match mounting holes, load point, thread, and installed height
- Confirm cell count and junction-box wiring
- Confirm material and protection rating for the environment
- Confirm rated output, excitation, and input/output impedance
- Keep datasheets, photos, and old part numbers with the service record
05 / 07Dimensions and connectionsUse the available images to confirm the mechanical envelope and cable connection.

Dimension reference 06 / 07Technical dataCatalog attributes for this load cell.
Material Alloy steel Protection IP67 Signal Analog Manufacturer Zemic Manufacturer part number H9N-N10-125K-9B Capacity in pounds 125000 lb Accuracy C3/3000d Approval NTEP Class III L, 10,000 divisions and OIML R60 C3 Rated output 3.0 ± 0.003 mV/V Recommended excitation 5 ~ 12 VDC Maximum excitation 18 VDC Input impedance 700 ± 7 Ω Output impedance 703 ± 4 Ω Insulation resistance ≥ 5000 MΩ @ 50 VDC Combined error ≤ ±0.020 %FS (C3) Creep error ≤ ±0.016 %FS / 30 min (C3) Safe overload 150 %FS Ultimate overload 300 %FS Operating temperature −35 to +70 °C Number of wires 4 Output sensitivity 3.0 ± 0.003 mV/V Compensated temperature −10 to +40 °C 07 / 07Part number referenceOrder code and fit FAQ.
Product Order code Zemic H9N-125000lb H9N-N10-125K-9B Double-Ended Beam Load Cell 23020 Is the SKU enough to confirm replacement?
No. Use the SKU as the order code, then confirm model, capacity, dimensions, wiring, signal, and environment.
What if some catalog attributes are blank?
Treat blank attributes as items to confirm before ordering. The description only uses available catalog data and conservative application guidance.
Can WeightechUSA help identify a match?
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.
Talk to a WeightechUSA load-cell specialist.
Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm whether 23020 is the right fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305 Signal Analog Protection class IP67 Material Alloy Steel Combined error ≤ ±0.020 %FS (C3) Compensated temp range −10 to +40 °C Creep error 20mins ≤ ±0.016 %FS / 30 min (C3) Input impedance 700 ± 7 Ω Insulation resistance ≥ 5000 MΩ @ 50 VDC Internal Battery -- Maximum excitation 18 VDC Maximum safe overload 150 %FS Minimum load cell verification interval Emax/10000 NTEP/OIML NTEP Class III L, 10,000 divisions · OIML R60 C3 Operating temp range −35 to +70 °C Output impedance 703 ± 4 Ω Rated capacity 125,000 lb Rated output 3.0 ± 0.003 mV/V Recommended excitation 5 ~ 12 VDC Ultimate central overload 300 %FS Manufacturer Zemic Accuracy C3/3000d Interchangeable Celtron CLB, Coti CI-58, Revere 5303, Sensortronics 65058, Tedea 4158, Rice Lake RL75058-LP Number of Wires 4 wires Manufacturer's Part Number H9N-N10-125K-9B Approval NTEP, OIML R60 C3 Short name H9N Load Cell · 125000 lb · H9N-N10-125K-9B Hero chips IP67; Alloy Steel; Analog signal; NTEP, OIML R60 C3; 4 wires