Berman Weighing Technology · Load cell
BTBI Shear Beam Load Cell · 1000 kg · BTBI-1tBerman BTBI-1t 1,000 kg Shear Beam Load Cell
SKU 10603
IP68; Alloy Steel; Analog signal; 2.0 ± 0.002 mV/V; 4 wires
84.00
- Description
- Additional Information
- 01 / 03Shear Beam Load Cell
Shear Beam Load Cell for confirmed-fit replacement and scale builds.
The Berman BTBI-1t is a 1,000 kg capacity variation of the Berman BTBI shear beam load cell family, manufactured in alloy steel with IP68 ingress protection.
1,000 kgRated capacityAlloy steelMaterialIP68Protection02 / 03Technical dataVerified specifications for this SKU.
Manufacturer Berman Manufacturer part number BTBI-1t Capacity 1,000 kg Rated output 2.0 ± 0.002 mV/V Dimensions 130 x 32 x 32 mm Input impedance 400 ± 20 Ω Output impedance 352 ± 3 Ω Insulation resistance ≥ 5000 MΩ Maximum excitation 15 VDC Compensated temperature −10 to +40 °C Operating temperature −30 to +70 °C Safe overload 150 %FS Ultimate overload 250 %FS Cable type 4 wires; 5m length; Ø5mm 03 / 03Part number referenceOrder code and fit FAQ.
Product Order code Berman BTBI-1t 1,000 kg Shear Beam Load Cell 10603 Is the SKU enough to confirm replacement?
Use the SKU and manufacturer part number above as the order code, then confirm wiring, signal, and environment with WeightechUSA before ordering.
Can WeightechUSA help identify a match?
Yes. Send photos of the installed cell, the label, mounting dimensions, cable colors, capacity, and the scale application.
Talk to a WeightechUSA load-cell specialist.
Send the old load-cell label, capacity, dimensions, cable details, and application. We will confirm the manufacturer part number and fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305DIMENSIONSOutline dimensions.

Source: Weightech BTBI datasheet Signal Analog Protection class IP68 Material Alloy Steel Compensated temp range −10 to +40 °C Creep error 30 mins ± 0.05 for 2t | ± 0.02 for 5t | ± 0.03 for 10t Input impedance 400 ± 20 Ω Insulation resistance ≥ 5000 MΩ Internal Battery -- Maximum excitation 15 VDC Maximum safe overload 150 %FS Nominal temp range -30°C ~ +70°C Operating temp range −30 to +70 °C Output impedance 352 ± 3 Ω Rated capacity 1,000 kg Rated output 2.0 ± 0.002 mV/V Recommended excitation 10~12 VDC Safe sideload 250 kg to 5t: 150% of Capacity | 10t: 120% of Capacity Sensitivity 2.0 ± 0.002 mV/V Ultimate central overload 250 %FS Manufacturer Berman Weighing Technology Cable type 4 wires; 5m length; Ø5mm Class C3 Number of Wires 4 wires Manufacturer's Part Number BTBI-1t Short name BTBI Shear Beam Load Cell · 1000 kg · BTBI-1t Hero chips IP68; Alloy Steel; Analog signal; 2.0 ± 0.002 mV/V; 4 wires