The Laumas TLB4MODBUSTCP is the Modbus/TCP output/fieldbus option of the Laumas TLB4 digital weight transmitter family.
| Manufacturer | Laumas |
| Manufacturer part number | TLB4MODBUSTCP |
| Output/Fieldbus | Modbus/TCP |
| Channels | 4 independent load-cell inputs |
| Power supply | 12-24 VDC +/-10%, 5 W |
| Load cells | Up to 16 x 350 ohm, 4/6-wire, 5 VDC/240 mA excitation |
| A/D converter | 4 channels, 24-bit (16,000,000 points), 4.8 kHz |
| Measurement range | +/-39 mV |
| Usable load cell sensitivity | +/-7 mV/V |
| Linearity | <0.01% full scale |
| Thermal drift | <0.0005% full scale/degC |
| Display | 6-digit semi-alphanumeric red LED, 8 mm height, +/-999999 range |
| Relay outputs | 3, max 115 VAC/150 mA |
| Optoisolated digital inputs | 2, 5-24 VDC PNP |
| Enclosure | Back-panel mounting on Omega/DIN rail, 115 x 26 x 120 mm |
| Humidity | 85% (condensate-free) |
| Storage temperature | -30 C to +80 C |
| Working temperature | -20 C to +60 C |
| Legal-for-trade approval | OIML R76:2006 Class III, 3x10,000 divisions, 0.25 uV/V*SI; OIML R61, R51 - WELMEC Guide 8.8:2017 (MID); UL Recognized component; NMI Trade Approved (Australia); New Zealand legal-for-trade use |
| Port | Modbus/TCP (RJ45 10Base-T or 100Base-TX, auto-sensing) |
| Network role | Slave in a Modbus/TCP network |
| Serial port | RS485 (included) |
| Product | Order code |
|---|---|
| Laumas TLB4MODBUSTCP Modbus/TCP Digital Weight Transmitter | 23100 |
Use the SKU and manufacturer part number above as the order code, then confirm wiring, signal, and environment with WeightechUSA before ordering.
Yes. Send photos of the installed equipment, the label, the model and option you need, and the application.
Send the model, the option you need, and the application. We will confirm the manufacturer part number and fit.
Email SalesView DatasheetCall +1 (954) 666-0877 × 305| Input power supply | 12-24 VDC +/-10%; 5 W |
|---|---|
| Internal Battery | -- |
| Storage temp range | -30 degC +80 degC |
| Fieldbus | Modbus/TCP |
| Linearity - Analog output linearity (only for TLB4) | <0.01% full scale |
| Thermal Drift | <0.0005% full scale/degC |
| A/D Converter | 4 channels - 24 bit (16000000 points) - 4.8 kHz |
| Measurement range | +/-39 mV |
| Usable load cells sensitivity | +/-7 mV/V |
| Display range | +/-999999 |
| Relay outputs | 3 - max 115 VAC/150 mA |
| Optoisolated digital inputs | 2 - 5-24 VDC PNP |
| Serial ports | RS485 |
| Humidity | 85% |
| Working temp range | -20 degC +60 degC |
| Manufacturer's Part Number | TLB4MODBUSTCP |
| Short name | TLB4 Weight Transmitter · Modbus/TCP · TLB4MODBUSTCP |
| Hero chips | Modbus/TCP; RS485; 12-24 VDC |